Showing 37–45 of 5072 results

Show sidebar

BENTLY NEVADA 330400 and 330425 Accelerometer Acceleration Transducers

Specifications Parameters are specified from +20 to +30 °C (+68 to +86 °F) and 100 Hz unless otherwise indicated. Operation outside the specified limits may result in false readings or loss of machine monitoring. Electrical 330400 Sensitivity 10.2 mV/m/s2 (100 mV/g) ±5%. Acceleration range 490 m/s2 (50 g) peak overall acceleration within the 10 Hz to 15 kHz frequency span. Vibration at frequencies above 15 kHz, especially at the transducers resonance will significantly decrease this range. Amplitude Linearity ±1% to 490 m/ s2 (50 g) peak. Broadband Noise Floor (10 Hz to 15 kHz) 0.039 m/s2 (0.004 g) rms. 330425 Sensitivity 2.5 mV/m/s2 (25 mV/g) ±5%. Acceleration Range 735 m/s2 (75 g) peak overall acceleration within the 10 Hz to 15 kHz frequency span. Vibration at frequencies above 15 kHz, especially at the transducer’s resonance, will significantly decrease this range. Amplitude Linearity ±1% to 735 m/s2 (75 g) peak. Broadband Noise Floor (10 Hz to 15 kHz) 0.098 m/s2 (0.01 g) rms. Both Units Frequency Response 10 Hz to 15 kHz (600 cpm to 900,000 cpm) ±3dB; 30 Hz to 10 kHz (1800 cpm to 600,000 cpm) ±10% Temperature Sensitivity -11% to +3% typical over the operating temperature range. Transverse Sensitivity Less than 5% of axial. Mounted Resonant Frequency Greater than 30 kHz. Amplitude of Resonant Peak 20 dB maximum. Base Strain Sensitivity For serial numbers preceded by the letter “G” (including all new sensors 49 mm/s2/mstrain (0.005 g/mstrain) For serial numbers NOT preceded by the letter “G” (shipped prior to April 2004) 980 mm/s2/mstrain (0.100 g/mstrain) without Mounting Base (API adapter); 4.9 mm/s2/mstrain (0.0005 g/mstrain) with Mounting Base (API adapter) supplied with the accelerometer. Bently Nevada recommends installing with the Mounting base to minimize base strain sensitivity for serial numbers NOT preceded by the letter “G”. Maximum cable length 305 metres (1000 ft) with no degradation of signal. Power requirements Input Voltage -24 ± 0.5 Vdc. Bias Current 2 mA nominal. Output Bias Voltage: -8.5 ± 0.5 Vdc. Grounding Case isolated. Environmental Limits 330400 and 330425 Accelerometer Acceleration Transducers Datasheet 2/10 141638 Rev. W Operating and storage temperature -55°C to +121°C (-67°F to +250°F) Shock Survivability 49,050 m/s2 (5000 g) peak, maximum. Relative humidity 100% condensing, non-submerged. Case is hermetically sealed. Magnetic Field Susceptibility <2.21 mm/s2/gauss (225 mg/gauss) [50 gauss, 50-60Hz]. IP Rating Equivalent to an IP 68 (Dust tight and watertight). Please note that this is for the sensor only and does not apply to the cable. Physical Weight (no cable) 99 g (3.5 oz), typical Diameter 23 mm (0.93 in). Height 59 mm (2.3 in), including mounting stud. Connector 3-pin MIL-C-5015 Receptacle 316L stainless steel Mounting Surface 32 minch rms. Mounting Torque 4.1 N·m (3.0 ft·lb). Case Material 316L stainless steel Weight (no cable) 100 g (3.5 oz), typical Mounting Angle Any orientation 330400 and 330425 Accelerometer Acceleration Transducers

BENTLY NEVADA PROXIMITY SENSOR – 9200-03-05-10-00

Proximity Sensor Model: 9200 - Two-Wire Seismoprobe Velocity Transducer Bently Nevada Seismoprobe Velocity Transducer Systems are designed to measure absolute (relative to free space) bearing housing, casing, or structural vibration. The two- wire systems consist of a transducer and appropriate cable. The Seismoprobe family of velocity transducers is a two- wire design that uses moving- coil technology. It provides a voltage output directly proportional to the transducer's vibration velocity. Moving- coil transducers are less sensitive to impact or impulsive excitation than solid- state velocity transducers, which are inherently accelerometers with embedded integration electronics. Moving- coil transducers are less sensitive to impact or impulsive excitation and can represent a good choice for certain applications. Because they don’t require external power, they are convenient for portable measurement applications. For most installations, Bently Nevada's Velomitor family of velocity transducers, which incorporate solid- state technology, provide improved performance and ruggedness for casing velocity measurement applications.

LA MARCHE Battery Charger – TPSD-30-130V-5BL1-92N

Detail LA MARCHE Battery Charger - TPSD-30-130V-5BL1-92N

The La Marche model TPSD is a controlled ferroresonant float charger designed to power a load while charging the battery. The TPSD is filtered and may be used without the battery. The all solid state electronic control circuit provides excellent line-load voltage regulation, current limiting, and a power failure relay with light and Form “C” contacts. The TPSD is offered with DC output voltages of 24, 48, or 130VDC with output currents from 6 to 200 Amps. These chargers may be powered with 120, 208, 240, or 480VAC. Understanding the Model Number The TPSD model number is coded to describe the options that are included. Find the model number on the nomenclature nameplate of the charger. Then follow the chart to determine the configuration of your battery charger.

La MARCHE – A77 SCR Battery Charger

Microprocessor Controlled SCR Technology Output: 24,48,130, 260 VDC 6-500 Amps Input: Single Phase:120/208/240/480/600 VAC Three Phase: 208/240/480/600 VAC

La Marche Battery Charger – MSM-40-12V-U1/MSM-60-12V-U1/MSM-80-12V-U1

Charger Specifications : Model Number Nomenclature Model Number DC Amps DC Volts AC Voltage Code AC Phase Code Factory Assigned Accessory Code MSM - 20 - 24V - U1 - ( ) AC Voltage Code U1 - 102-264 VAC AC Phase Code 1 - Single Phase LCD Display AC Input Wide AC Input Range 102 - 264VAC Single Phase 45 - 65 Hz DC Output 10 - 80A / 12V 10 - 65A / 24V Power Factor 0.99 Load Regulation <±0.5% Input Protection Fuse with Surge and Transient Protection AC Over Voltage Protection Output Protection Current Limit Protection Fuse with Surge Protection Reverse Current Polarity Thermal Protection Short Circuit Protection LED Indicators Current Limit AC ON Charger Fail Low Current

La Marche Battery Charger – MSM-10-24V-U1 / MSM-20-24V-U1 / MSM-20-24V

Charger Specifications : Model Number Nomenclature Model Number DC Amps DC Volts AC Voltage Code AC Phase Code Factory Assigned Accessory Code MSM - 20 - 24V - U1 - ( ) AC Voltage Code U1 - 102-264 VAC AC Phase Code 1 - Single Phase LCD Display AC Input Wide AC Input Range 102 - 264VAC Single Phase 45 - 65 Hz DC Output 10 - 80A / 12V 10 - 65A / 24V Power Factor 0.99 Load Regulation <±0.5% Input Protection Fuse with Surge and Transient Protection AC Over Voltage Protection Output Protection Current Limit Protection Fuse with Surge Protection Reverse Current Polarity Thermal Protection Short Circuit Protection LED Indicators Current Limit AC ON Charger Fail Low Current

La Marche Battery Charger – MSM-65-24V-U1 / MSM-50-24V-U1 / MSM-35-24V

Charger Specifications : Model Number Nomenclature Model Number DC Amps DC Volts AC Voltage Code AC Phase Code Factory Assigned Accessory Code MSM - 20 - 24V - U1 - ( ) AC Voltage Code U1 - 102-264 VAC AC Phase Code 1 - Single Phase LCD Display AC Input Wide AC Input Range 102 - 264VAC Single Phase 45 - 65 Hz DC Output 10 - 80A / 12V 10 - 65A / 24V Power Factor 0.99 Load Regulation <±0.5% Input Protection Fuse with Surge and Transient Protection AC Over Voltage Protection Output Protection Current Limit Protection Fuse with Surge Protection Reverse Current Polarity Thermal Protection Short Circuit Protection LED Indicators Current Limit AC ON Charger Fail Low Current

La Marche Battery Charger – MSM-30-24V-U1

Charger Specifications *Weight does not include shipping packaging Model Number Nomenclature Model Number DC Amps DC Volts AC Voltage Code AC Phase Code Factory Assigned Accessory Code MSM - 20 - 24V - U1 - ( ) AC Voltage Code U1 - 102-264 VAC AC Phase Code 1 - Single Phase LCD Display AC Input Wide AC Input Range 102 - 264VAC Single Phase 45 - 65 Hz DC Output 10 - 80A / 12V 10 - 65A / 24V Power Factor 0.99 Load Regulation <±0.5% Input Protection Fuse with Surge and Transient Protection AC Over Voltage Protection Output Protection Current Limit Protection Fuse with Surge Protection Reverse Current Polarity Thermal Protection Short Circuit Protection LED Indicators Current Limit AC ON Charger Fail Low Current Alarm Contacts Charger Failure LCD Digital Display AC Input Voltmeter DC Output Voltmeter and Ammeter (1%) Environmental Operating: -20° to 50°C (-4° to 122°F) Storage: -40° to 85°C (-40° to 185°F) Relative Humidity: 0 to 95% non condensing Adjustable Voltage Range 10.4 to 14.1 (12V) 20.8V to 28.2V (24V) Mounting Wall mount Cable Entry Bottom Finish Powder coated aluminum enclosure (corrosion resistant) Standards UL 1236, ABS & USCG Requirements EN 60335-1 (Electrical Safety) IEC 60335-2-29 (Electrical Safety) IEC 60068-2-6 (Sinusoidal Vibration) EN 55011 (Radiated EMI) IEC 1000-4-2 (Electrostatic Discharge) IEC 1000-4-4 (Electrical Fast Transient)

LA MARCHE Battery Charger – A77DE-35-24V-5BL1-20N – X

A77DE-35-24V-5BL1-20N - X Microprocessor Controlled SCR Filtered/Eliminator 35 Amp DC Output 24 Volt DC Output 50 HZ Input 240 Vac Input Single Phase Input 20 Nickel Cells