BENTLY NEVADA 330400 and 330425 Accelerometer Acceleration Transducers
Specifications
Parameters are specified from +20 to +30 °C
(+68 to +86 °F) and 100 Hz unless otherwise
indicated.
Operation outside the specified limits may
result in false readings or loss of machine
monitoring.
Electrical
330400
Sensitivity 10.2 mV/m/s2 (100 mV/g) ±5%.
Acceleration
range
490 m/s2 (50 g) peak overall
acceleration within the 10 Hz to 15
kHz frequency span. Vibration at
frequencies above 15 kHz, especially
at the transducers resonance will
significantly decrease this range.
Amplitude
Linearity
±1% to 490 m/ s2 (50 g) peak.
Broadband
Noise Floor
(10 Hz to 15
kHz)
0.039 m/s2 (0.004 g) rms.
330425
Sensitivity 2.5 mV/m/s2 (25 mV/g) ±5%.
Acceleration
Range
735 m/s2 (75 g) peak overall
acceleration within the 10 Hz to 15
kHz frequency span. Vibration at
frequencies above 15 kHz, especially
at the transducer’s resonance, will
significantly decrease this range.
Amplitude
Linearity
±1% to 735 m/s2 (75 g) peak.
Broadband
Noise Floor
(10 Hz to 15
kHz)
0.098 m/s2 (0.01 g) rms.
Both Units
Frequency
Response
10 Hz to 15 kHz
(600 cpm to 900,000 cpm) ±3dB;
30 Hz to 10 kHz
(1800 cpm to 600,000 cpm) ±10%
Temperature
Sensitivity
-11% to +3% typical over the
operating temperature range.
Transverse
Sensitivity
Less than 5% of axial.
Mounted
Resonant
Frequency
Greater than 30 kHz.
Amplitude of
Resonant
Peak
20 dB maximum.
Base Strain Sensitivity
For serial
numbers
preceded by
the letter “G”
(including all
new sensors
49 mm/s2/mstrain (0.005 g/mstrain)
For serial
numbers NOT
preceded by
the letter “G”
(shipped
prior to April
2004)
980 mm/s2/mstrain (0.100 g/mstrain)
without Mounting Base (API
adapter);
4.9 mm/s2/mstrain (0.0005 g/mstrain)
with Mounting Base (API adapter)
supplied with the accelerometer.
Bently Nevada recommends
installing with the Mounting base to
minimize base strain sensitivity for
serial numbers NOT preceded by the
letter “G”.
Maximum
cable length
305 metres (1000 ft) with no
degradation of signal.
Power requirements
Input Voltage -24 ± 0.5 Vdc.
Bias Current 2 mA nominal.
Output Bias
Voltage:
-8.5 ± 0.5 Vdc.
Grounding Case isolated.
Environmental Limits
330400 and 330425 Accelerometer Acceleration Transducers
Datasheet
2/10 141638 Rev. W
Operating
and storage
temperature
-55°C to +121°C (-67°F to +250°F)
Shock
Survivability
49,050 m/s2 (5000 g) peak, maximum.
Relative
humidity
100% condensing, non-submerged.
Case is hermetically sealed.
Magnetic
Field
Susceptibility
<2.21 mm/s2/gauss (225 mg/gauss)
[50 gauss, 50-60Hz].
IP Rating Equivalent to an IP 68 (Dust tight and
watertight). Please note that this is
for the sensor only and does not
apply to the cable.
Physical
Weight (no
cable)
99 g (3.5 oz), typical
Diameter 23 mm (0.93 in).
Height 59 mm (2.3 in), including mounting
stud.
Connector 3-pin MIL-C-5015 Receptacle
316L stainless steel
Mounting
Surface
32 minch rms.
Mounting
Torque
4.1 N·m (3.0 ft·lb).
Case Material 316L stainless steel
Weight (no
cable)
100 g (3.5 oz), typical
Mounting
Angle
Any orientation
330400 and 330425 Accelerometer Acceleration Transducers
BENTLY NEVADA PROXIMITY SENSOR – 9200-03-05-10-00
Proximity Sensor
Model: 9200 - Two-Wire Seismoprobe Velocity Transducer
Bently Nevada Seismoprobe Velocity Transducer Systems are designed to measure absolute (relative to free space) bearing housing, casing, or structural vibration. The two- wire systems consist of a transducer and appropriate cable. The Seismoprobe family of velocity transducers is a two- wire design that uses moving- coil technology. It provides a voltage output directly proportional to the transducer's vibration velocity. Moving- coil transducers are less sensitive to impact or impulsive excitation than solid- state velocity transducers, which are inherently accelerometers with embedded integration electronics. Moving- coil transducers are less sensitive to impact or impulsive excitation and can represent a good choice for certain applications. Because they don’t require external power, they are convenient for portable measurement applications. For most installations, Bently Nevada's Velomitor family of velocity transducers, which incorporate solid- state technology, provide improved performance and ruggedness for casing velocity measurement applications.
LA MARCHE Battery Charger – TPSD-30-130V-5BL1-92N
Detail LA MARCHE Battery Charger - TPSD-30-130V-5BL1-92N
The La Marche model TPSD is a controlled ferroresonant float charger designed to power a load while charging the battery. The TPSD is filtered and may be used without the battery. The all solid state electronic control circuit provides excellent line-load voltage regulation, current limiting, and a power failure relay with light and Form “C” contacts. The TPSD is offered with DC output voltages of 24, 48, or 130VDC with output currents from 6 to 200 Amps. These chargers may be powered with 120, 208, 240, or 480VAC. Understanding the Model Number The TPSD model number is coded to describe the options that are included. Find the model number on the nomenclature nameplate of the charger. Then follow the chart to determine the configuration of your battery charger.
La MARCHE – A77 SCR Battery Charger
Microprocessor Controlled SCR Technology
Output:
24,48,130, 260 VDC
6-500 Amps
Input:
Single Phase:120/208/240/480/600 VAC
Three Phase: 208/240/480/600 VAC
La Marche Battery Charger – MSM-40-12V-U1/MSM-60-12V-U1/MSM-80-12V-U1
Charger Specifications :
Model Number Nomenclature Model Number DC Amps DC Volts AC Voltage Code AC Phase Code Factory Assigned Accessory Code MSM - 20 - 24V - U1 - ( ) AC Voltage Code U1 - 102-264 VAC AC Phase Code 1 - Single Phase LCD Display AC Input Wide AC Input Range 102 - 264VAC Single Phase 45 - 65 Hz DC Output 10 - 80A / 12V 10 - 65A / 24V Power Factor 0.99 Load Regulation <±0.5% Input Protection Fuse with Surge and Transient Protection AC Over Voltage Protection Output Protection Current Limit Protection Fuse with Surge Protection Reverse Current Polarity Thermal Protection Short Circuit Protection LED Indicators Current Limit AC ON Charger Fail Low Current
La Marche Battery Charger – MSM-10-24V-U1 / MSM-20-24V-U1 / MSM-20-24V
Charger Specifications :
Model Number Nomenclature Model Number DC Amps DC Volts AC Voltage Code AC Phase Code Factory Assigned Accessory Code MSM - 20 - 24V - U1 - ( ) AC Voltage Code U1 - 102-264 VAC AC Phase Code 1 - Single Phase LCD Display AC Input Wide AC Input Range 102 - 264VAC Single Phase 45 - 65 Hz DC Output 10 - 80A / 12V 10 - 65A / 24V Power Factor 0.99 Load Regulation <±0.5% Input Protection Fuse with Surge and Transient Protection AC Over Voltage Protection Output Protection Current Limit Protection Fuse with Surge Protection Reverse Current Polarity Thermal Protection Short Circuit Protection LED Indicators Current Limit AC ON Charger Fail Low Current
La Marche Battery Charger – MSM-65-24V-U1 / MSM-50-24V-U1 / MSM-35-24V
Charger Specifications :
Model Number Nomenclature Model Number DC Amps DC Volts AC Voltage Code AC Phase Code Factory Assigned Accessory Code MSM - 20 - 24V - U1 - ( ) AC Voltage Code U1 - 102-264 VAC AC Phase Code 1 - Single Phase LCD Display AC Input Wide AC Input Range 102 - 264VAC Single Phase 45 - 65 Hz DC Output 10 - 80A / 12V 10 - 65A / 24V Power Factor 0.99 Load Regulation <±0.5% Input Protection Fuse with Surge and Transient Protection AC Over Voltage Protection Output Protection Current Limit Protection Fuse with Surge Protection Reverse Current Polarity Thermal Protection Short Circuit Protection LED Indicators Current Limit AC ON Charger Fail Low Current
La Marche Battery Charger – MSM-30-24V-U1
Charger Specifications *Weight does not include shipping packaging Model Number Nomenclature Model Number DC Amps DC Volts AC Voltage Code AC Phase Code Factory Assigned Accessory Code MSM - 20 - 24V - U1 - ( ) AC Voltage Code U1 - 102-264 VAC AC Phase Code 1 - Single Phase LCD Display AC Input Wide AC Input Range 102 - 264VAC Single Phase 45 - 65 Hz DC Output 10 - 80A / 12V 10 - 65A / 24V Power Factor 0.99 Load Regulation <±0.5% Input Protection Fuse with Surge and Transient Protection AC Over Voltage Protection Output Protection Current Limit Protection Fuse with Surge Protection Reverse Current Polarity Thermal Protection Short Circuit Protection LED Indicators Current Limit AC ON Charger Fail Low Current Alarm Contacts Charger Failure LCD Digital Display AC Input Voltmeter DC Output Voltmeter and Ammeter (1%) Environmental Operating: -20° to 50°C (-4° to 122°F) Storage: -40° to 85°C (-40° to 185°F) Relative Humidity: 0 to 95% non condensing Adjustable Voltage Range 10.4 to 14.1 (12V) 20.8V to 28.2V (24V) Mounting Wall mount Cable Entry Bottom Finish Powder coated aluminum enclosure (corrosion resistant) Standards UL 1236, ABS & USCG Requirements EN 60335-1 (Electrical Safety) IEC 60335-2-29 (Electrical Safety) IEC 60068-2-6 (Sinusoidal Vibration) EN 55011 (Radiated EMI) IEC 1000-4-2 (Electrostatic Discharge) IEC 1000-4-4 (Electrical Fast Transient)
LA MARCHE Battery Charger – A77DE-35-24V-5BL1-20N – X
A77DE-35-24V-5BL1-20N - X
Microprocessor Controlled
SCR Filtered/Eliminator
35 Amp DC Output
24 Volt DC Output
50 HZ Input
240 Vac Input
Single Phase Input
20 Nickel Cells